BALCO Tracking Chart TCR

Characteristic in ppm/°F.
Fohmsppm/°Fchg.°Fohmsppm/°Fchg.
32918.5333920.621212.154
34922.7121222.15535924.7921242.157
36926.8621262.15937928.9821272.16
38931.0721292.16239933.1921302.163
40935.2821312.16541937.4121322.166
42939.5121342.16843941.6521352.169
44943.7521372.17145945.8921382.172
4694821402.17347950.1221422.175
48952.2721432.17649954.3921452.178
50956.5421462.17951958.6721482.181
52960.821502.18353962.9621512.184
54965.121522.18655967.2621532.187
56969.4321542.18857971.5821562.19
58973.7321582.19259975.8921602.194
60978.0621612.19561980.2321632.197
62982.4121642.19863984.5821662.2
64986.7721672.20165988.9521692.203
66991.1421702.20467993.3221732.206
68995.5121732.20769997.7121742.208
70100021742.207711002.1121782.212
721004.3121792.213731006.5121822.216
741008.7321832.217751010.9421852.219
761013.1621872.22771015.3821882.222
781017.621892.223791019.8321922.226
801022.0521912.225811024.2821922.226
821026.5221942.228831028.7521952.229
841031.0121982.232851033.2421982.232
861035.522012.236871037.7422012.235
881039.9822022.237891042.2422042.239
901044.4922052.24911046.7722082.242
921049.0222082.242931051.2722092.243
941053.5722122.246951055.8522142.248
961058.1122152.249971060.3822162.25
981062.6922182.253991064.9722192.254
1001067.2422202.2552121342.7223882.42

TEMPERATURE COEFFICIENT OF RESISTANCE (TCR)

• The TCR equals the change in resistance times 1,000,000 (106) divided by the original resistance (Ro) times the change in temperature.

• The TCR Char. is calculated between 25°C. and 100°C., always using +25°C.(77°F.) as the base temperature in the equation:

TCR/°F. = R212°F. – R77°F. / R77°F. x 135 x 106
= 1342.72 – 1015.38 / 1015.38 x 135 x 106
= 2388 ppm/°F. TCR/°C. = R100°C. – R25°C. / R25°C. x 75 x 106
= 1342.72 – 1015.38 / 1015.38 x 75 x 106
= 4298 ppm/°C.